Prodotti della ricerca

 
Titolo: Agreement between multidetector-row CT angiography and ultrasound echo-color Doppler in the evaluation of carotid artery stenosis
Autori: 
Data di pubblicazione: 2008
Rivista: 
CEREBROVASCULAR DISEASES  
Citazione: Agreement between multidetector-row CT angiography and ultrasound echo-color Doppler in the evaluation of carotid artery stenosis / Saba L; Sanfilippo R; Montisci R; Mallarini G.. - In: CEREBROVASCULAR DISEASES. - ISSN 1015-9770. - 26:5(2008), pp. 525-532.
Abstract: PURPOSE: Stroke is a leading cause of severe disability in the western world. A correct diagnostic procedure to stratify risk is necessary in order to rapidly plan the most efficient therapy. The purpose of this work was to evaluate the agreement between ultrasound echo-color Doppler (US-ECD) and multidetector-row CT angiography (MDCTA) in determining the degree of carotid stenosis. METHODS AND MATERIALS: From January 2004 to February 2007, 187 patients who had previously undergone both US-ECD and MDCTA were studied retrospectively. For each patient, stenosis degree was measured by applying the North American Symptomatic Carotid Endarterectomy Trial criteria. Data derived from MDCTA and US-ECD were then compared to calculate the inter-technique variability by using Cohen kappa statistics. For all plaque types (fatty, mixed and calcified), inter-technique variability was assessed. The Wilcoxon signed-rank test was used to highlight differences between the procedures, and scatterplots were also calculated. As a gold standard, reference surgical comparisons were performed in 50 patients. RESULTS: The percentage of observed agreements in the evaluation of stenosis degree was 72.19% with a kappa value of 0.659 (95% confidence interval: 0.604-0.715) and a weighted kappa of 0.789. After the evaluating stenosis degree in fatty, mixed and calcified plaques, the percentages of observed agreements were 79.31, 74.58 and 64.29%, respectively, with kappa values of 0.738, 0.691 and 0.565. CONCLUSION: A good agreement between US-ECD and MDCTA in the evaluation of stenosis degree was observed, together with a remarkable difference between the 2 techniques in the assessment both of calcified plaques and of plaques showing a predominant calcific component.
Handle: http://hdl.handle.net/11584/103731
Tipologia:1.1 Articolo in rivista

File in questo prodotto:
Non ci sono file associati a questo prodotto.
credits unica.it | accessibilità Università degli Studi di Cagliari
C.F.: 80019600925 - P.I.: 00443370929
note legali | privacy

Nascondi la toolbar